ĐẠI LÝ PHÂN PHỐI CHÍNH THỨC METRIX - ANS VIETNAM

Metrix Vietnam Electronic Vibration switch 440 DR-2201-0005
2: 4-20mA, absolute
2: 3.0-4.0mm/SEC
0: TRIAC, 5A, SPST
1: TRIAC, 5A
0: CSA, class 1, GPRS B,C&D
0: 115VAC, 50/60Hz
0: No Lock out function
5: SA6200 constant current accelerometer
Metrix Vietnam Proximity PP 10026-02-12-10-02
Reverse Mount Prox. Probe, 3/8"-24 threads, 0.5 or 1.0 m length (no armor, connector included)
(Code: 10026-02-12-10-02) 
Metrix Vietnam Shaker HI 803-120V
Portable Shaker, Variable Frequency and Amplitude Control, Manual and Sensitivity Modes (Sensitivity Mode tests the transducer and provides a mV/unit output to compare with the sensor manufacturer's specifications), Built-in self-test program, Built-In Printer with paper, Data Storage, RS-232 port and data transfer software, 120V, Standard Accessories, CE Approved
(HI 830)
Metrix Vietnam Shaker HI 803-240V
Same as the HI 803-240V, except the voltage requirement is 240 Volts
(HI 830)
Metrix Vietnam Model: ST5484E-151-131-00
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
151: Full Scale Range - 1.0 ips (25.4mm/SEC), RMS
1: Mounting Stud - INTEGRAL 1/2" NPT STUD MOUNT, 303 SST
3: Hazard Rating - ATEX, Ex ia IIC, T4, Intrinsically Safe
1: Connection -  4-20mA, Dynamic Signal, Flying Leads
0: High Pass Filter - No Filter (2 Hz), Standard
0: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
126: Full Scale Range - 0.8 ips (20.3mm/SEC), pk
10: Mounting Stud - INTEGRAL 1/4" NPT STUD MOUNT, 316 SST
1: Hazard Rating - Non-Hazardous, CSA, NRTL/C, Class 1, Div 2, Grps A, B, C & D
2: Connection -  4-20mA, 2 Pin Terminal Block
0: High Pass Filter - No Filter (2 Hz), Standard
0: Low Pass Filter - No Filter (1500 Hz), Standard
(ST5484E-126-1012-00)
Metrix Vietnam Seismic ST 5484E-121-1182-00 (ST5484E-121-1182-00)
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
121: Full Scale Range - 1.0 ips (25.4mm/SEC), pk
11: Mounting Stud - INTEGRAL 1/2" NPT STUD MOUNT, 316 SST
8: Hazard Rating -ATEX/IECEx, Ex d IIC T4
2: Connection -  4-20mA, 2 Pin Terminal Block
0: High Pass Filter - No Filter (2 Hz), Standard
0: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Seismic ST 5484E-123-1182-00 (ST5484E-123-1182-00)
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
123: Full Scale Range - 2.0 ips (50.8mm/SEC), pk
11: Mounting Stud - INTEGRAL 1/2" NPT STUD MOUNT, 316 SST
8: Hazard Rating -ATEX/IECEx, Ex d IIC T4
2: Connection -  4-20mA, 2 Pin Terminal Block
0: High Pass Filter - No Filter (2 Hz), Standard
0: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Seismic SV 5485C-008
5485C-AAA  Velocity Sensor - 375°C max., connector version (X= 2, 4, 6 or 8)
(Code: 5485C-008)
Metrix Vietnam Seismic AC 4850-XXX
Cable Assembly - High Temperature ( 5485)      Cable length must be in even increments past 20ft. 
Example: Requested 21ft.  Offer 4850-022 (22ft.) 
(Code: 4850-020)
Metrix Vietnam Seismic AC 4850-XXX
Cable Assembly - High Temperature ( 5485)      Cable length must be in even increments past 20ft.  Example: Requested 21ft.  Offer 4850-022 (22ft.) 
(Code: 4850-010)
Metrix Vietnam Model: ST5484E-123-020-00
Seismic ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
123 : Full Scale Range - 2.0 ips (50.8mm/SEC), pk 0: Mounting Stud - INTEGRAL 1/4" NPT STUD MOUNT, 303 SST
2: Hazard Rating - CSA, NRTL/C, Class 1, Div 1, Grps B, C & D, Class 2, Div 1, Grps E, F & G
0: Connection -  4-20 mA Flying Leads (C=1 or 2)
0: High Pass Filter - No Filter (2 Hz), Standard 0: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Cable
7402-040-00
Metrix Vietnam Cable
7402-045-00
Metrix Vietnam Cable
7402-080-00
Metrix Vietnam Cable
7402-080-01
Metrix Vietnam Cable
9282-045-00
Metrix Vietnam Cable
9282-080-00
Metrix Vietnam Cable
9282-085-00
Metrix Vietnam Switch
SW6000-3333-400
Metrix Vietnam Sensor
5485C-008
Metrix Vietnam Cable
7402-085-01
Metrix Vietnam Housing
8200-002
Metrix Vietnam SA6200UW Underwater Acclerometer
Ordering code: SA6200UW01015 (15 meter cable)
Metrix Vietnam Seismic
Correct: SV 5485C-007-010  
Velocity Sensor - 375°C max., with -010 ft. fixed cable (1st X = 1, 3, 5 or 7)
(Model: 5485C-007-010
Sensitivity: 150 mv/ips
Termination: Fixed cable
Max temp: 200oC)
Metrix Vietnam Seismic
Correct: SV 5485C-007-020 
Velocity Sensor - 375°C max., with -020 ft. fixed cable (1st X = 1, 3, 5 or 7)
(Model: 5485C-007-020
Sensitivity: 150 mv/ips
Termination: Fixed cable
Max temp: 375oC)
Metrix Vietnam Elec Switch SW6000-3332-400
3: Limits & Displays - One limit, FET, w/o display
33: Full Scale Range - 20 mm/sec, RMS
2: Input Power - 230 VAC, single phase, 50/60 Hz
4: Certifications Local Reset Options -  CE and CENELEC EEx d IIB + H2, T4
0: Input/Output Options – None
0: Mounting/Conduit Entries - 1/2" NPT stud mount / 3/4" NPT conduit entry
Metrix Vietnam Seismic 5485C-003-006
5485C-AAA-BBB  Velocity Sensor - 375°C max., with -XXX ft. fixed cable (1st X = 1, 3, 5 or 7)
Metrix Vietnam Code: 5485C-AAA Velocity Sensor with Removable Cable
Ordering Code: 5485C-006
Description:  5485C-AAA  Velocity Sensor - 375°C max., connector version (X= 2, 4, 6 or 8)
Metrix Vietnam Proximity PP 10026-02-12-10-02
Reverse Mount Prox. Probe, 3/8"-24 threads, 0.5 or 1.0 m length (no armor, connector included)
(Code: 10026-02-12-10-02) 
Metrix Vietnam Code: ST5484E-151-432-00    
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
-151: Full Scale Range - 1.0 ips (25.4mm/SEC), RMS
4: Mounting Stud - M8 X 1.0 -12 STUD MOUNT, 303 SST
3: Hazard Rating - ATEX, Ex ia IIC, T4, Intrinsically Safe
2: Connection -  4-20mA, 2 Pin Terminal Block
-0: High Pass Filter - No Filter (2 Hz), Standard
0: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Mech Switch MW 5550-411-361
MW 5550: 5550-ABC-DEF    Mechanical Vibration Switch (Base Model)
A: Hazard Rating - ATEX, IECEx Flame Proof, Ex d IIB + H2, T6 (B=1 or 2)
B: Contacts – SPDT
C: Full Scale Range - 5 g
D: Reset Coil & Start Up Delay - 24 VDC, 3.0A - 10g / 2.5A - 5g / 1.2A - 2g (If C=2, unit may not be mounted horizontally)
E: Wiring Entry/Mounting Plate - M20 X 1.5;  METRIX 5173 / 5175
F: Environmntal Rating - NEMA 4X, IP 66, CE
(5550-411 -361)
Metrix Vietnam Seismic ST 5484E-121-032-00 (ST5484E-121 -032-00)
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
A: Full Scale Range - 1.0 ips (25.4mm/SEC), pk
B: Mounting Stud - INTEGRAL 1/4" NPT STUD MOUNT, 303 SST
C: Hazard Rating - ATEX, Ex ia IIC, T4, Intrinsically Safe
D: Connection -  4-20mA, 2 Pin Terminal Block
E: High Pass Filter - No Filter (2 Hz), Standard
F: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Seismic ST 5484E-121-132-00 (ST5484E-121-132-00)
ST5484E-AAA-BCD-EF    IPT Seismic vibration transmitter, loop powered (Base Model)
A: Full Scale Range - 1.0 ips (25.4mm/SEC), pk
B: B: Mounting Stud - INTEGRAL 1/2" NPT STUD MOUNT, 303 SST
C: Hazard Rating - ATEX, Ex ia IIC, T4, Intrinsically Safe
D: Connection -  4-20mA, 2 Pin Terminal Block
E: High Pass Filter - No Filter (2 Hz), Standard
F: Low Pass Filter - No Filter (1500 Hz), Standard
Metrix Vietnam Code: ST5491E-022-020-0-0
Seismic vibration transmitter, loop powered, with LCD indication (Base Model)