Đầu dò nhiệt độ BS-21K-010-TC1-ANP Anritsu vietnam
Giá bán: Vui lòng liên hệ
Xuất sứ: Japan
Hãng sản xuất: Anritsu vietnam
Gọi điện thoại đặt mua: 0902.337.066
ĐẠI LÝ PHÂN PHỐI ANRITSU VIETNAM-ĐẠI LÝ ANS VIETNAM
Model BS series
General Internal Probes
Model BS series probes are internal temperature sensors designed to measure the temperatures of liquid or semi-solid materials.
Specific components may be combined to customize products for the needs of a customer's specific application
Type E Model BS-21E-010-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 500°C | ±2.5°C * | 2.5 s | B |
Type E Model BS-91E-003-TS1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 0.5 s | C |
Type E Model BS-22E-010-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 200°C | ±2.5°C * | 20 s | B |
Type E Model BS-31E-030-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 500°C | ±2.5°C * | 3.0 s | B |
Type E Model BS-11E-003-TS1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 1.5 s | C |
Type E Model BS-51E-100-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 500°C | ±2.5°C * | 5.0 s | B |
Model BT series
Needle Type Probes
Model BT series probes feature needle tips that can be inserted into semi-solid materials.
Needle tips for models with replaceable tips can be purchased separately.
Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model BT-31E-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 1.5 s | S |
Type E Model BT-72E-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 1.5 s | S |
Type E Model BT-11E-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 210°C | ±2.5°C * | 0.5 s | C |
Type E Model BT-92E-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 500°C | ±2.5°C * | 3.0 s | B |
Type E Model BT-22E-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 1.5 s | C |
Type E Model BTN-41E
Temp. Range | Tolerance | Response time | Durability |
-200 to 300°C | ±2.5°C * | 1.5 s | S |
Model SF series
Fine Flexible Probes
Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model SF-E-100-ANP
Temp. Range | Tolerance | Response time | Durability |
-50 to 200°C | ±2.5°C * | 2.0 s | S |
Type E Model SF-E-200-ANP
Temp. Range | Tolerance | Response time | Durability |
-50 to 200°C | ±2.5°C * | 2.0 s | S |
Model AT series
Air Temperature Probes
Model AT series probes are Air temperature sensors designed to measure the temperature of Air.
Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model AT-10E-050-0-TS1-ANP
Temp. Range | Tolerance | Response time | Durability |
-50 to 200°C | ±2.5°C * | 0.3 s | S |
Type E Model AT-30E-050-1-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-50 to 500°C | ±2.5°C * | 0.3 s | S |
Model SHEATH series
Bendable Wiry Probes
Model SHEATH series probes are internal temperature sensors designed to measure the temperature of liquids, air, and gases.
The sheathed section can be bent to a radius five times the outer diameter of the sheath.
Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model B3.2-E-J1-M1-L500-TC1-ANP
Temp. Range | Tolerance | Response time | Durability |
-50 to 750°C | ±2.5°C * | 5.0 s | S |
Form | A | Grip type | |
B | Sleeve type | ||
C | Terminal box type | ||
AH | Grip type/Teflon coating | ||
BH | Sleeve type/Teflon coating | ||
CH | Terminal box type/Teflon coating | ||
Diameter | 0.25 | φ0.25mm | |
0.5 | φ0.5mm | ||
1.0 | φ1.0mm | ||
1.6 | φ1.6mm | ||
3.2 | φ3.2mm | ||
4.8 | φ4.8mm | ||
6.4 | φ6.4mm | ||
8.0 | φ8.0mm | ||
Thermocouple Type | K | Chromel-Alumel | |
E | Chromel-Constantan | ||
Junction | J1 | Grounded junction | |
J2 | Ungrounded junction | ||
J3 | Exposed junction | ||
Material | M1 | SUS 316 | |
M2 | SUS 310S (Only type K) | ||
M3 | Inconel (Only type K) | ||
Sheath Length | L100 | 100mm | |
L200 | 200mm | ||
… | …… | ||
Cable Type see cable page |
TC | More than φ1mm in sheath diameter | |
TS | φ0.25mm,φ0.5mm in sheath diameter | ||
Cable Length | 1 | 1000mm | |
1.5 | 1500mm | ||
2 | 2000mm | ||
… | …… | ||
Plug see plug page |
ANP | ||
ASP | |||
W |
You can choose Form as below.
Models with an outer sheath diameter of φ0.25 / 0.5mm have sleeve dimensions of φ5 × 30mm and no spring.
The sheath tube can be coated with Teflon.
Teflon coating will improve resistance against chemicals and enable the use of the probe for measuring the temperatures of acids alkalis, food. etc.
Applicable sheath diameter : φ1.0, φ1.6, φ3.2
Maximum length : 1m
Operating temperature limit : 200°C
Minimum bending radius : Approx. 10mm
Outside diameter (mm) | 0.25 | 0.5 | 1.0 | 1.6 | 3.2 | 4.8 | 6.4 | 8.0 | |
Type : K Max.temp.(°C) | SUS316(M1) | — | — | 650 | 650 | 750 | 800 | 800 | 900 |
SUS310S(M2) | — | — | 650 | 650 | 750 | 800 | 800 | 900 | |
Inconel(M3) | 500 | 500 | 650 | 650 | 750 | 900 | 1000 | 1050 | |
Type : E Max.temp.(°C) | SUS316(M1) | — | — | 650 | 650 | 750 | 800 | 800 | 800 |
Response time (sec.) | 0.4 | 0.9 | 2 | 3 | 5 | 10 | 15 | 20 | |
Standard resistance (Ω / m) | Type : K | 570 | 124 | 32 | 13 | 4 | 2.2 | 1.0 | 0.7 |
Type : E | — | ― | 38 | 15 | 5 | 2.6 | 1.2 | 0.9 | |
Max. Length (m) | J1, J3 | 5 | 10 | 50 | 50 | 50 | 50 | 30 | 20 |
J2 | 2 | 2 | 2 | 5 | 15 | 30 | 30 | 20 | |
Tolerance | Type : K | -40 to 333°C : ±2.5°C, 333 to 1200°C : ±(measuring×0.75%)°C | |||||||
Type : E | -40 to 333°C : ±2.5°C, 333 to 900°C : ±(measuring×0.75%)°C |
■ : Thermocouple type K or E
t : Measured temperature
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 500°C | ±(0.0075×|t|)°C |
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 650°C | ±(0.0075×|t|)°C |
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 750°C | ±(0.0075×|t|)°C |
A6.4-■-J*-M1 / A6.4-K-J*-M2 / A8.0-E-J*-M1
B4.8-■-J*-M1 / B4.8-K-J*-M2
B6.4-■-J*-M1 / B6.4-K-J*-M2 / B8.0-E-J*-M1
C4.8-■-J*-M1 / C4.8-K-J*-M2
C6.4-■-J*-M1 / C6.4-K-J*-M2 / C8.0-E-J*-M1
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 800°C | ±(0.0075×|t|)°C |
B4.8-K-J*-M3 / B8.0-K-J*-M1 / B8.0-K-J*-M2
C4.8-K-J*-M3 / C8.0-K-J*-M1 / C8.0-K-J*-M2
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 900°C | ±(0.0075×|t|)°C |
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 1000°C | ±(0.0075×|t|)°C |
Temperature range | Tolerance (Internal) |
-40°C ≦ t < 333°C | ±2.5°C |
333°C ≦ t ≦ 1050°C | ±(0.0075×|t|)°C |
Temperature range | Tolerance (Internal) |
-40°C ≦ t ≦ 200°C | ±2.5°C |
Model BR series
Low Temperature Probes
Specific components may be combined to customize products for the needs of a customer's specific application.
Type E Model BR-10E-1-TS1-ANP
Temp. Range | Tolerance | Response time | Durability |
-100 to 200°C | ±2.5°C * | 1.5 s | C |
Type E Model BR-10E-0-TS1-ANP
Temp. Range | Tolerance | Response time | Durability |
-100 to 200°C | ±2.5°C * | 1.5 s | C |