ĐẠI LÝ PHÂN PHỐI DATAPAQ VIETNAM-ANSVIETNAM

Datapaq Vietnam Model: CC0037     
Robust Hard Carry Case.
For use with Furnace, Kiln and specialized Oven Systems.
Datapaq Vietnam Model: PA0712
Thermocouple, Mineral Insulated, Type K, Length 3.0m, 1.6mm
diameter, Nicrobell™ sheath.
Operating Range: 0°C-1250°C.
Fitted with miniature high temperature plug for direct connection into data logger
Datapaq Vietnam Miniature plug for PA0717 and PA0183
For existing thermocouple
Note: Checking
Datapaq Vietnam TB4956
4900 Series Thermal Barrier, Recommended Data Loggers: TP2016,
DQ1860.
310 Grade Stainless Steel construction, Microporous insulation with phase change heat sink, Mullite textile lined, User replaceable thermocouple wear strip, Datapaq
Floating Plate™ Technology. Duration: 1 hour 15min.@1000°C, 2 hours@800°C, 2 hours 45min.@600°C, 4 hours 15min.@400°C, 8 hours @ 200°C.
Dimensions: 154mm(H) x 275mm(W) x 409mm(L), 529mm(Length over handles).
Weight:17.35kg.
Datapaq Vietnam TP2016
Tpaq21, 10 Channel data logger, temperature measuring range -100°C to +1370°C, type K, 70°C ambient temperature operat ion
Accuracy +/- 0.3°C*, total memory 130,000 data point s over 10 channels. Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes possible per run.
Maximum ambient operating temperature 70°C. Uses r echargeable NiMH battery complete with charger. Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H). USB communications cable
supplied (CI1031). *(Contact Datapaq for accuracy -100°C to -190°C).
Datapaq Vietnam SW5030
Datapaq Insight for Furnace Software, Language Variants
Temperature profiling and analysis software with full real-time monitoring functionality. Includes real time alarm functions, event marker facility, and Wizards to help the infrequent user. French SW5031; German SW5032; Spanish SW5033;
Portuguese SW5034; Japanese SW5035; Simplified Chinese SW5036; Italian
SW5037; Korean SW5038; Slovak SW5039; Czech SW50310; Traditional
Chinese SW30311; Russian SW50312; Vietnamese SW50314.
Datapaq Vietnam PA0717
Thermocouple, Mineral Insulated, Type K, Length 10m, 1.6mm
diameter, Nicrobell™ sheath.
Operating Range: 0°C-1250°C.
Fitted with miniature high temperature plug for direct connection into data logger
Datapaq Vietnam PA0183
Heavy Duty Exposed Junction Thermocouple Length 5.0m
Type K Dual Layer Fiberglass Braid (High Temperature Varnish x2 Coats)) 0.3 mm
(28 AWG) Single Strand Wire Accuracy +/- 0.4% or +/- 1.1 °C (2.0 °F) ANSI
MC96.1 special limits of error Maximum Intermittent Temperature 800 °C
Maximum Continuous Temperature 700 C
Datapaq Vietnam As the maximum temperature is 400degC, we have to use a high temperature thermal barrier.  For this application, our recommended solution is such:
System model number: FTL-24-95 comprising
SW5220 (Insight Lite Software – English)
DQ1860 (6-channel Q18 Data Logger)
TB2005 (Thermal Barrier able to withstand 400degC for 22 mins)
PA0181 x 6 pcs (Heavy Duty Exposed Junction Thermocouple 2m length, 0.3mm diameter)
CC0048 (Soft Carry Bag)
Note that DP9061 (Datapaq 9000) is obsolete and no longer in production
(Option 1
Full set :
Dataloger : DP9061
Barier : TB5000
Soft : SW5210
Within Thermocouple
USB cable
Option 2
Full set :
Data
Dataloger : ET6061
Barier : TB5000
Soft : SW5210
Within Thermocouple
USB cable)
Datapaq Vietnam Datapaq XL2 8 channel 
System Components:
SW5000-P Insight Professional Software for Oven Tracker (Language Variants)
Includes Operator Manual and Quick Reference Guide. Compatible with Oven Tracker XL2, Q18
and Tpaq21 loggers.
x 1
XL2 8CH Transducer Interface XL2 and Mempaq Set (8 Channel)
8 Channel XLTI (TI0080) and MemoryPaq XL2 (MP0050). Temperature range: -200ÅC to
1,370ÅC. Type K thermocouple. Cold junction compensation guaranteeing accuracy up to 85ÅC.
Individually calibrated channels. Operating temperature 85ÅC. NiMH rechargeable battery. USB
comms via cable CI1150. Supersedes obsolete MP0030. Compatible with v6.0 Insight software
only. Supplied with charger cable CH0070.
x 1
TB0090 Standard Thermal Barrier.
Accepts Oven Tracker XL2 Loggers (6/8 Channels)
Silicone free/Aluminium construction.
Suitable heatsink: 1 x TB9950.
Duration: 1 hour @ 300ÅC, 3 hours @ 200ÅC, 11 hours @ 100ÅC.
Dimensions: 134mm(H) x 187mm(W) x 296mm(L)
Weight: 3.65kg (including heatsink)
x 1
PA2050 Thermocouple Cable Tidy
Keep cable routing even, prevent kinking and tangling. Easy thermocouple identification.
Secures up to 8 cables.
x 1
PA2051 Thermocouple ID Tags
Aluminium ID tags fitted to the sensor end of the thermocouple cable to allow clear identification of
the thermocouple number or channel, even when the barrier is closed.
x 1
PA2052 Hanging Storage Strap
Hang mild steel strap from the barrier; attach clamp thermocouples to transport safely. Also
provides tidy storage facility for clamp or magnetic thermocouples.
x 1
PA0054 Magnetic Surface Thermocouple,  length 3.0m. PTFE Cable.
PTFE Insulated cable, 0ÅC to 265ÅC maximum
x 7
PA0056 Magnetic Air Thermocouple,  length 3.0m. PTFE Cable.
PTFE Insulated cable, 0ÅC to 265ÅC maximum
x 1
CC0057 XL2 Robust Hard Carry Case
For use with XL2 system.
x 1
Datapaq Vietnam PA0712
Thermocouple, Mineral Insulated, Type K, Length 3.0m, 1.6mm
diameter, Nicrobell™ sheath.
Operating Range: 0°C-1250°C.
Fitted with miniature high temperature plug for direct connection into data logger
Datapaq Vietnam Model: TP2085
(Datalogger : Tpaq21, Model TP2085A, SN : 30491) 
 
Datapaq Vietnam Thermal barrier
TB5000
Weight: 6.2kg
Note:  Please check with customer their process maximum temperature and process duration.  Please also check customer’s Insight software version.  Only version 7.20 or later can be used with new logger.  If customer is having older version software, then they need to purchase software upgrade.  Please check which type of Insight software they are having.  Different software upgrade has different price.
Datapaq Vietnam Correct: PA0715SP 15m
(Model: PA0715
1.6mm dài 15m) 
Datapaq Vietnam Correct: PA0760SP 15m
(Model: PA0760
3mm  dài 15m)
Datapaq Vietnam Furnace Survey Software
SW5130
This comes in a DVD with an installation license number
(INSIGHT SURVEY ANALYSIS SOFTWARE)
Datapaq Vietnam P/N: PA0538
Kiln Tracker Thermocouple Probe, Type K, Length 2.0m.
Mineral Insulated, Nicrobell™ sheath, 3.0mm diameter, fitted with high temperature standard plug.  0€C to 1250€C maximum
Note: are you asking for thermocouples Type K?  We do not sell XDL12 system with standard set of thermocouples.  Hence, I do not know what thermocouples Type K they need.  Please check more details of what thermocouples they need (e.g. length, temperature measurement range, diameter, etc).
(XD0012 
Thermocouple type K)
Datapaq Vietnam Furnace Survey Software
SW5130
This comes in a DVD with an installation license number
(INSIGHT SURVEY ANALYSIS SOFTWARE)
Datapaq Vietnam Correct: Thermal Barrier TB4005
Recommended Data Logger: TP2016, TP2086, DQ1860.
Stainless Steel construction, Microporous insulation with phase change heat sink,
Mullite textile lined.  Duration: 1 hour@800C, 2 hours@400C, 6 hours@200C.
Dimensions: 125mm(H) x 248mm(W) x 409mm(504mm including handles)(L).
Weight: 11.95kg.
(Thermal Barrier TB4005C) 
Datapaq Vietnam Code: TP2016
Tpaq21, 10 Channel data logger, temperature measuring range -100 0C to +13700C, type K, 70€C ambient temperature operation
Accuracy +/- 0.3C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run. Maximum ambient operating temperature 700C.  Uses
rechargeable NiMH battery complete with charger. Hot data protection by non-
volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm
(H). USB communications cable supplied.
*(Contact Datapaq for accuracy -100C to -190C).
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam Code: TP2086
Tpaq21, 8 Channel data logger, temperature measuring range -100 0C
to +13700C, type K, 700C ambient temperature operation
Accuracy +/- 0.3C*, total memory 130,000 data points over 8 channels. Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes possible per run. Maximum ambient operating temperature 70 0C.  Uses rechargeable NiMH battery complete with charger. Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H). USB communications cable supplied (CI1031).
*(Contact Datapaq for accuracy -100C to -190C).
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam Code: DQ1860
Q18 Data Logger, 6 Channel, Type K Thermocouples, Range -2000C to 1,3700C
Accuracy00.5.C. 55,000 readings per channel (6 Channels Active).
Programmable time/temp trigger. Sampling interval 0.05s to 10min. Rechargeable
NiMH Battery with Fast Charger.   USB communications port. Dims: 150mm(L) x
106mm(W) x 12mm(H)
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam 2m thermocouple with 1.6mm diameter
P/N: PA0711
Datapaq Vietnam Correct: Thermal Barrier TB4005
Recommended Data Logger: TP2016, TP2086, DQ1860.
Stainless Steel construction, Microporous insulation with phase change heat sink,
Mullite textile lined.  Duration: 1 hour@800C, 2 hours@400C, 6 hours@200C.
Dimensions: 125mm(H) x 248mm(W) x 409mm(504mm including handles)(L).
Weight: 11.95kg.
(Thermal Barrier TB4005C) 
Datapaq Vietnam Code: TP2016
Tpaq21, 10 Channel data logger, temperature measuring range -100 0C to +13700C, type K, 70€C ambient temperature operation
Accuracy +/- 0.3C*, total memory 130,000 data points over 10 channels.
Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes
possible per run. Maximum ambient operating temperature 700C.  Uses
rechargeable NiMH battery complete with charger. Hot data protection by non-
volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm
(H). USB communications cable supplied.
*(Contact Datapaq for accuracy -100C to -190C).
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam Code: TP2086
Tpaq21, 8 Channel data logger, temperature measuring range -100 0C
to +13700C, type K, 700C ambient temperature operation
Accuracy +/- 0.3C*, total memory 130,000 data points over 8 channels. Sampling interval 0.1s to 50 minutes, with up to 8 sampling interval changes possible per run. Maximum ambient operating temperature 70 0C.  Uses rechargeable NiMH battery complete with charger. Hot data protection by non-volatile memory and software.
Dimensions: 200 mm (L) x 98 mm (W) x 20 mm (H). USB communications cable supplied (CI1031).
*(Contact Datapaq for accuracy -100C to -190C).
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam Code: DQ1860
Q18 Data Logger, 6 Channel, Type K Thermocouples, Range -2000C to 1,3700C
Accuracy00.5.C. 55,000 readings per channel (6 Channels Active).
Programmable time/temp trigger. Sampling interval 0.05s to 10min. Rechargeable
NiMH Battery with Fast Charger.   USB communications port. Dims: 150mm(L) x
106mm(W) x 12mm(H)
(Temperature Measuring Equipment TPAQ21)
Datapaq Vietnam As the maximum temperature is 400degC, we have to use a high temperature thermal barrier.  For this application, our recommended solution is such:
System model number: FTL-24-95 comprising
SW5220 (Insight Lite Software – English)
DQ1860 (6-channel Q18 Data Logger)
TB2005 (Thermal Barrier able to withstand 400degC for 22 mins)
PA0181 x 6 pcs (Heavy Duty Exposed Junction Thermocouple 2m length, 0.3mm diameter)
CC0048 (Soft Carry Bag)
Note that DP9061 (Datapaq 9000) is obsolete and no longer in production
(Option 1
Full set :
Dataloger : DP9061
Barier : TB5000
Soft : SW5210
Within Thermocouple
USB cable
Option 2
Full set :
Data
Dataloger : ET6061
Barier : TB5000
Soft : SW5210
Within Thermocouple
USB cable)
Datapaq Vietnam System: FTL-91-95
SW5220 (Insight Lite Software – English)
DQ1860 (6-channel Q18 Data Logger)
TB4056 (Thermal Barrier able to withstand 600degC for 2.75hrs)
PA0181 x 6 pcs (Heavy Duty Exposed Junction Thermocouple 2m length, 0.3mm diameter)
CC0048 (Soft Carry Bag)
Shipping Weight: 22kg